Diamond Wheel Dressing Solution Resistors - Thin Film Microwave & RF Solitec Spinners, Coaters and Developer support Storage Cabinets (Dry / Nitrogen & Custom) Tapes (Wafer, Dicing & Protective) Tape / Film Applicator / Mounters UV Curing Control & Test Equipment
Links
|
PUMP ACCESSORIES
UV Process Supply offers a wide range of replacement parts and accessories for the Con-Trol_CureTM line of pumps. Eliminate downtime and stock up on
Generous
assortment of 76 fittings has everything you need for
laboratory set-ups. Clear, hinged polystyrene storage case
makes it easy to find what you need. Intended for low
pressure applications (20 PSI or less).
This Black
Tubing for Peristaltic Pumps is available with ID
measurements of 5/16", 3/8", 1/2", and
5/8". This tubing, made of Santoprene, offers good
mechanical properties under a wide range of operating
temperatures. Highly durable, it is resistant to fatigue,
ozone, ultraviolet, acids, alkalies, water, and most oils
and lubricants.
CON-TROL-CURE™ In-Line Strainer provides pump protection, nozzle protection, or can be used for most applications where contaminants need to be removed from air or liquid lines. Molded of durable plastic which is resistant to solvents and UV coatings. Strainers are reinforced with tough stainless steel ferrules. Sediment is collected inside the screen for ultimate protection. Pumps fitted with the In-Line Strainer have been observed to last longer and operate with less maintenance. Recommended for use with 1/4" Double Diaphragm and Transfer Pump installations. Replacement screen also available to ensure longevity. J004-013 PMPAC:STRAINER INLINEJ004-016 STRAINER REPLACEMENT SCREEN
Filter/Magnet
System - Small particles circulating through the inking
system can lodge behind the doctor blade causing damage to
the roll. These particles can pass to the printing plate
and may cause a pinholing effect resulting in print
imperfections. The MDC Filter/Magnet System has extensive
field testing and is highly effective in removing
particles caused by doctor blades, ink pump impellers,
dried ink, paper dust and other debris. Benefits of the
system include significant cost savings, longer lasting
cylinders and cleaner print. J004-301 DTWYLR:RAREARTH HOLDER
Don't buy a new pump, buy the CON-TROL-CURE™ Pump Adaptor! This universal Pump Adaptor converts all 2" National Pipe Thread to a 2" buttress thread. Works in conjunction with all drum pumps. Made of an engineered resin. J004-140 PUMP ADAPTOR
PVC Tubing is
available in either Black or Clear, which MUST be
specified when ordering.
TECHNICAL DATA
Replacement Silicone Tubing is specially designed for peristaltic pumps. The translucent, clear to light amber, peroxide-cured tubing is compatible with UV fluids. 5 ft and 25 ft lengths available, please specify I.D. (inside diameter): 1/4" or 5/16". J004-074C PERISTALTIC TUBING 1/4" I.D.J004-075C PERISTALTIC TUBING 3/8" I.D.
The convenient
Stopcock Tube Screw Clamp features complete on/off and
fine control settings with enough accuracy to replace
stopcocks in many pump applications. Hinged side permits
installation of clamp without disconnecting tubing from
apparatus or interrupting operation. Constructed of
durable Delrin acetal homopolymer. Easy to clean,
autoclavable and highly resistant to alkalies, weak acids
and organic solvents. Accepts any type of flexible tubing
up to 1/2" O.D. (12.7 mm).
This snap grip acetal Tube Clamp secures hose and tubing in seconds. Snap shut with pliers. Secure, safe and economical. Simple twist action with pliers removes clamp. Hose size 5/8" or 3/4". J004-008 TUBE CLAMP 3/4"J004-021 TUBE CLAMP 5/8"
For use with
CON-TROL-CURE® pumps, CON-TROL-CURE® Hose has been
selected for its compatibility with radiation curable
formulations. Transport Hose will not swell or break down
with UV curable materials. J008-003 TRANSPORT HOSE 3/4" J008-005 TRANSPORT HOSE 1/2" FITTING BARBED U-BEND CONNECTOR
Barbed U-Bend Fitting is safe to use with UV inks and coatings due to durable, stainless steel construction. Will resist rust and corrosion. 3/8" U-Bend with 3/8" barbed stem. J004-109 BARBED UBEND 3/8"
Filter/Magnet
System - Small particles circulating through the inking
system can lodge behind the doctor blade causing damage to
the roll. These particles can pass to the printing plate
and may cause a pinholing effect resulting in print
imperfections. The MDC Filter/Magnet System has extensive
field testing and is highly effective in removing
particles caused by doctor blades, ink pump impellers,
dried ink, paper dust and other debris. Benefits of the
system include significant cost savings, longer lasting
cylinders and cleaner print. J004-303 DTWYLR: FILTER ADAPTER
J004-304 DTWYLR:
STRAINER
POLYETHYLENE LW DENSITY LINEAR TUBING
Linear Low Density Polyethylene Tubing J004-200 PMPAC:.170-.040 PLYTBHAND VALVE ELLIPTICAL POLYPROPYLENE
The unique
design of the Elliptic Hand Valves offers unmatched
suitability for a broad range of applications in fluid
handling systems, especially where a high degree of
resistance to corrosion and contamination is required. J004-038 VALVE 3WAY 2 POSITION J004-039 VALVE 3WAY 4 POSITION
Molded from high density polyethylene resins, these fittings are non-corrosive and will withstand pressures up to 200 PSI. To assemble, simply push tubing over serrated end of fitting and attach clamp if necessary. 3/8" fittings are offered for CON-TROL-CURE® Transfer Pumps; 1/2" fittings are intended for the CON-TROL-CURE® All FLow Pump and Peristaltic Pumps.
The Standard Walled PVC Tubing is available with ID measurements of 1/2", 5/8", 3/4", 7/8", 1" and 1-1/4". This general purpose tubing offers high performance at a low cost. It is flexible and offers a broad range of chemical resistance,
BALL VALVE STAINLESS STEEL SHUTOFF
The 3/8" heavy-duty, In-Line Ball Valves feature 303 stainless steel construction and Teflon® seat material for durable on/off flow control of air or material lines. Handles pressures up to 6,000 PSI (413 bar). J004-080 PMPAC:VALVE 3/8 SSTEEL
Double
Diaphragm Pumps offer many benefits over most other types
of reciprocating pumps. They do, however, present the
drawback of pulsation. For a steady stream, the
CON-TROL-CURE® Surge Suppressor acts as a shock absorber
to cushion the effects of pulsating flow. Basically
constructed as closed chambers, each model contains an
elastomer bladder inside. The bladder separates a
compressed air cushion on the top from the pumped liquid
on the bottom. To control surges from delivery discharges,
the Surge Suppressor should be installed at the pump's
discharge connection. The closer to the pump discharge,
the better the dampening effect. 2 models available: for
1/2" or 1/4" flexible air hoses. J004-052 PMPAC:SURGE
SUPRES 1/2
This small bore silicone tubing is highly resistant to UV chemistry and associated chemicals. It is UV grade, food grade, peroxide cured and FDA approved. USA Pharmacpia XIX Class VI. This tubing has a wall thickness of .9 mm and is available in the following I.D. (inside diameters):.38 mm, .51 mm, .64 mm, .76 mm, .89 mm, 1.02 mm, 1.14 mm, 1.30 mm, 1.42 mm, 1.52 mm, 1.65 mm, 2.06 mm, 2.29 mm, 2.54 mm, 2.79 mm. Sold in 15 m rolls. J004-150 PMPAC:SILICONE TUBING
18/01/2012 03:50 |
|
|
Adhesives & Epoxies - Bonding Tools - CO2 Cleaning - Thin Film & Thick Film Resistors - Electronic Packages - Dispensing Equipment - Micro Abrasive Systems - Die Bonders - Dicing Tape & Applicators - Dry Storage Cabinets - Thermal Interface Materials - UV Curing Systems & Accessories - Solderability Test Equipment - Steam Agers - Epak Custom Equipment - Custom Machine Guarding All Information and images are © copyright of Epak Electronics Ltd and our Principle Companies. No unauthorised duplication. |