UV CURING SYSTEM EQUIPMENT
    
  
AUTOMATION
ADHESIVE BONDING
INKJET
PRINTER CURING LAMPS
LARGE
AREA FLOOD CURING LAMPS
BALLASTS
AND POWER SUPPLIES
ELECTRONIC
POWER SUPPLIES ( BALLASTS )
LAMP
VOLTAGE INTERFACE LVI
LIGHTHOUSE
SYSTEMS (UV REFLECTOR HOUSING)
UV
EQUIPMENT PARTS & ACCESSORIES
AUTOMATION
ADHESIVE BONDING

Why restrict
your adhesive applications to a limited type of lamp
configuration? Now you can apply adhesives to a variety of
substrates including glass, metals, plastics and vinyls.
With Con-Trol-Cure’s exclusive AUTOMATION ADHESIVE
BONDING CURING LAMP SYSTEM you can instantly cure
adhesives onto almost any surface. Reduce production
schedules, increase output and save money with this
revolutionary new curing system that will literally change
the way you use your current adhesive systems. Our new
AUTOMATION ADHESIVE BONDING CURING LAMP SYSTEM offers the
following features:
• Solid state electronic ballast powers two lamps
simultaneously; each lamp has a maximum power output of
400 watts
• Power supply input voltage 200-300 VAC; 47-63 Hertz
• Power can be switched from 320 to 350 or 400 watts and
is dimmable from 100% to 50% power in all wattage settings
• Box mounted with full power level switching
• Available with or without solenoid activated shutter
system to control and direct light
• Lamp housings are fan-cooled
• ¾ ellipse reflector
• 18” standard fully adjustable flexible arm
[customizable]
• 8 meter lamp power connection
• 3-4 week lead time
A014-003: AUTOMATION ADHESIVE BONDING CURING-SHUTTERED
A014-004: AUTOMATION ADHESIVE BONDING CURING-NONSHUTRD
INKJET
PRINTER CURING LAMPS

CON-TROL-CURE’s
exclusive INKJET CURING LAMP SYSTEM has a small footprint
that can fit into the confined areas of most inkjet
printers. This lightweight lamp (only 2 lbs) is powered by
a solid-state electronic ballast, not magnetic as in many
other similar systems. This results in a significantly
lower priced offering-- more the 50% less expensive than
comparable lamps. The efficiency of the power supply
enables it to drive 2 lamp heads, doubling your light
production.
The innovative ¾ ellipse reflector sends more focussed
light towards your substrate. The specific geometry of
this lamp housing results in less light lost and minimal
light leakage, creating in a highly efficient system.
FEATURES:
• Solid state electronic ballast powers two lamps
simultaneously; each lamp has a maximum power output of
400 watts
• Output power for lamps can be user preset for 400
watts, 350 watts or 320 watts
• User interface provides step-less adjustment range
from 50% to 100% of preset power
• Power supply input voltage 200-300 VAC; 47-63 Hertz
• Available with or without solenoid activated shutter
system to
prevent heat and unwanted UV light from reaching substrate
• Lamp housings are fan-cooled
• ¾ ellipse reflector (100% focused light on substrate)
• 8 meter lamp power connection
• Weight: (unshuttered) 2 lbs (907 g)
(shuttered) 2.5 lbs (1134 g)
• Dimensions: Length: 7.75” (19.69 cm)
Width: 5.125” (13.02 cm)
Height: 6.5” (16.51 cm)
A014-001 INKJET
CURING: SHUTRD
A014-002 INKJET
CURING:NONSHTRD
LARGE
AREA FLOOD CURING LAMPS

The
CON-TROL-CURE® Wide Area Flood Curing Lamp is a UV
Process Supply exclusive and is ideal for UV curing an
expansive area. Fitted with adjustable lamp holders, this
new, large area UV Flood housing can accommodate lamps
with a total power from 250W up to 1,800W.
This unit casts an even irradiance over a wide area.
Placed at a distance of 3 feet from the material to be
cured, the Wide Area Flood Curing Lamp projects an
effective cure area of at least 5 feet by 5 feet. The lamp
housing can sit on a floor and shine up onto a wall. It
can also be mounted in almost any other position required,
using your own stand and/or supports.
The power supply that accompanies each system would be
determined based on the lamp power required. The
recommended light source is an Iron Additive lamp.
POTENTIAL CURING APPLICATIONS
• 3D objects
• Walls
• Automotive components
• Guitars
• And much more
FEATURES:
• Special angled reflector housing provides a wide flood
path of UV energy
• Built in cooling system, supplies the correct amount
of airflow to keep the lamp at a stable temperature,
providing a more consistent energy output.
• Thin reflector technology enables reflectors to be
kept at their optimum without major maintenance time.
• Easy installation, floor standing, wall or ceiling
mountable.
• One medium pressure Iron Additive lamp is included
800 - 1800W POWER SUPPLY SPECIFICATIONS:
Power: 110V, 17.5A, 60Hz. Includes cable to connect power
supply and irradiator
Controls: On/Off switch, ammeter, and indicator lights
Dimensions: 19”W x 20”D x 7- 5/16”H
International Power: Optional upgrade to 230V 50Hz
international power

BALLASTS
AND POWER SUPPLIES

CON-TROL-CURE®
Power Supplies are sold either encased (complete) or
unencased. The encased power supply includes all wiring to
ballast, control and high voltage DIN Rails (see next
page), capacitors, control panel switches, and display
meters. It is ready for use upon delivery. The unencased
unit contains the power supply and capacitors required for
operating a specified UV lamp. No wires or other related
components are included. It is an ideal solution for
replacing or upgrading components within an aging system.
Con-Trol-Cure’s® Encased Premium Power Supplies include
a variety of unique performance features custom designed
to match your specific UV lamp specifications.
ENCASED POWER SUPPLY FEATURES:
• Our exclusive Lamp Voltage Interface (LVI). Designed
specifically to monitor the high voltage draw of UV lamps,
the LVI’s numeric display can be directly associated
with the lamps' voltage consumption. This numeric data can
be collected to establish statistical benchmarks and track
the lamp’s performance. Once a baseline is established,
lamps requiring replacement can be easily identified prior
to causing any production issues.
• Thermal-safe overload switch shuts down system to
protect against overheating.
• Housing fan runs automatically and will shut down once
the housing is sufficiently cool.
• Control features include: on/off switch, ammeter, hour
meter, and indicator lights.
• Available in 300, 400, 600, and 750 WPI capacities.
• Basic Encased Power Supplies offer 3-level power
switching.
• Premium Encased Power Supplies offer 8-level power
switching.
ADDITIONAL POWER SUPPLIES:
• Dual Encased: Power 2 lighthouse irradiators from 1
unit.
• Pre-Wired Unencased: All the components offered in our
Basic Encased system, wired together and mounted to a
backplate. Allows easy incorporation into your equipment
housing. Ideal for applications requiring 4 or more power
supplies that require you to construct a centralized
control box housing.
• Unencased Ballast: Power supply and capacitors
required for operating a specified UV lamp. No wires or
other related components offered. Ideal for replacing or
upgrading components within an aging system.
To integrate unencased ballasts into a 3rd party
production system, the end user must provide all necessary
mercury relays and appropriate wiring. UV Process Supply
can provide recommendations and pricing for related
components such as timers, metal housings, and volt
interface units.
Replacement ballasts and related components are also
available for existing systems. To ensure that you receive
the correct parts for your system, please specify wattage,
part number, and quantity required. Individual replacement
parts for unencased systems, such as capacitors, relays,
and wiring, are also available. We can provide customized
ballasts to meet your specifications.
Important Note: UV Process Supply does not provide
engineering support or technical service for installation.
While our ballasts are suitable for emergency power
reduction switching, and can be interfaced with
temperature sensing devices, etc., the customer must
provide all electrical engineering and installation
expertise.
HOW TO IDENTIFY YOUR CON-TROL-CURE® POWER SUPPLY PART
NUMBER:
For the Basic Power Supply (with 3 power levels), the part
number is constructed as follows:
A031 - ### for unencased
A032 - ### for encased
The First "#" represents the first digit of the
W/Inch
ie: For an encased 400W/Inch power supply, the part number
would be A032-4##.
The next two ## represent the System's Arc Length
ie: For an unencased 300W/Inch power supply, 8" arc
length, the part number would be A031-308.
For a Premium Power Supply with 8-level power selection,
follow the same number sequence, but add a "P"
on the end. (For the standard 3-level power selection, no
changes to this number are required.)
ie: For the above item, A031-308, if a Premium Power
Supply, the part number would be A031-308P.
CON-TROL-CURE® DIN RAILS:
CON-TROL-CURE® offers 2, fully-wired, ready-to-install
DIN rails featuring all internal high/low voltage
electrical and switching components for interfacing your
ballast and UV lamp. System includes:
• Main Power/Control DIN Rail
Pre-wired, 2-position mounting bracket incorporates all
switching relays (including mercury), timer, fuses and
grounding. Color-coded and numerically-coded with diagrams
for quick, error-free installation.
• High Power DIN Rail
Pre-wired, 2-position mounting bracket includes
high/low/medium volt interface (up to 2000W) and grounding
on 2-position mounting bracket. Color-coded and
numerically-coded with diagrams for quick, error-free
installation.
| A003-003 |
EQUIP:BLST 1600W UNENC |
| A004-002 |
CAP:BRACKET 3 1/2" |
| A004-009 |
CAPACITOR:CHASSIS (4) |
| A031-306 |
EQBL:UNENCS 6IN 300 |
| A031-308 |
EQBL:ENCS 8IN 300WPI |
| A031-310 |
EQBL:UNENCS 10IN 300W |
| A031-312 |
EQBL:UNENCS 12IN 300W |
| A031-315 |
EQBL:UNENCS 15IN 300W |
| A031-318 |
EQBL:UNENCS 18IN 300W |
| A031-320 |
EQBL:UNENCS 20IN 300W |
| A031-325 |
EQBL:UNENCS 25IN 300W |
| A031-330 |
EQBL:UNENCS 30IN 300W |
| A031-332 |
EQBL:UNENCS 32IN 300W |
| A031-338 |
EQBL:UNENCS 38IN 300W |
| A031-342 |
EQBL:UNENCS 42IN 300W |
| A031-348 |
EQBL:UNENCS 48IN 300W |
| A031-350 |
EQBL:UNENCS 50IN 300W |
| A031-355 |
EQBL:UNENCS 5IN 300W |
| A031-360 |
EQBL:UNENCS 60IN 300W |
| A031-365 |
EQBL:UNENCS 65IN 300W |
| A031-372 |
EQBL:UNENCS 72IN 300W |
| A031-377 |
EQBL:UNENCS 77IN 300W |
| A031-406 |
EQBL:UNENCS 6IN 400W |
| A031-408 |
EQBL:UNENCS 8IN 400W |
| A031-410 |
EQBL:UNENCS 10IN 400W |
| A031-412 |
EQBL:UNENCS 12IN 400W |
| A031-415 |
EQBL:UNENCS 15IN 400W |
| A031-418 |
EQBL:UNENCS 18IN 400W |
| A031-420 |
EQBL:UNENCS 20IN 400W |
| A031-425 |
EQBL:UNENCS 25IN 400W |
| A031-426 |
EQBL:UNENCS 26IN 400W |
| A031-430 |
EQBL:UNENCS 30IN 400W |
| A031-432 |
EQBL:UNENCS 32IN 400W |
| A031-434 |
EQBL:UNENCS 34IN 400W |
| A031-438 |
EQBL:UNENCS 38IN 400W |
| A031-442 |
EQBL:UNENCS 42IN 400w |
| A031-448 |
EQBL:UNENCS 48IN 400W |
| A031-450 |
EQBL:UNENCS 50IN 400W |
| A031-455 |
EQBL:UNENCS 55IN 400W |
| A031-460 |
EQBL:UNENCS 60IN 400W |
| A031-465 |
EQBL:UNENCS 65IN 400W |
| A031-472 |
EQBL:UNENCS 72IN 400W |
| A031-477 |
EQBL:UNENCS 77IN 400W |
| A032-306 |
EQBPS:BSC ENC 6IN 300W |
| A032-306P |
EQPPS:PRE ENC 6IN 300W |
| A032-308 |
EQBPS:BSC ENC 8IN 300W |
| A032-308P |
EQPPS:PRE ENC 8IN 300W |
| A032-310 |
EQBPS:BSC ENC10IN 300W |
| A032-310P |
EQPPS:PRE ENC10IN 300W |
| A032-312 |
EQBPS:BSC ENC12IN 300W |
| A032-312P |
EQPPS:PRE ENC12IN 300W |
| A032-318 |
EQBPS:BSC ENC18IN 300W |
| A032-318P |
EQBPS:BSC ENC18IN 300W |
| A032-320 |
EQBPS:BSC ENC20IN 300W |
| A032-325 |
EQBPS:BSC ENC25IN 300W |
| A032-325P |
EQPPS:PRE ENC25IN 300W |
| A032-332 |
EQBPS:BSC ENC32IN 300W |
| A032-332P |
EQPPS:PRE ENC32IN 300W |
| A032-338 |
EQBPS:BSC ENC38IN 300W |
| A032-338P |
EQPPS:PRE ENC38IN 300W |
| A032-342 |
EQBPS:BSC ENC42IN 300W |
| A032-342P |
EQPPS:PRE ENC42IN 300W |
| A032-348 |
EQBPS:BSC ENC48IN 300W |
| A032-348P |
EQPPS:PRE ENC48IN 300W |
| A032-350 |
EQBPS:BSC ENC50IN 300W |
| A032-350P |
EQPPS:PRE ENC50IN 300W |
| A032-355 |
EQBPS:BSC ENC55IN 300W |
| A032-355P |
EQPPS:PRE ENC55IN 300W |
| A032-360 |
EQBPS:BSC ENC60IN 300W |
| A032-360P |
EQPPS:PRE ENC60IN 300W |
| A032-365 |
EQBPS:BSC ENC65IN 300W |
| A032-365P |
EQPPS:PRE ENC65IN 300W |
| A032-372 |
EQBPS:BSC ENC72IN 300W |
| A032-372P |
EQPPS:PRE ENC72IN 300W |
| A032-377 |
EQBPS:BSC ENC77IN 300W |
| A032-377P |
EQPPS:PRE ENC77IN 300W |
| A032-406 |
EQBPS:BSC ENC 6IN 400W |
| A032-406P |
EQPPS:PRE ENC 6IN 400W |
| A032-408 |
EQBPS:BSC ENC 8IN 400W |
| A032-408P |
EQPPS:PRE ENC 8IN 400W |
| A032-410 |
EQBPS:BSC ENC 10IN400W |
| A032-410P |
EQPPS:PRE ENC 10IN400W |
| A032-412 |
EQBPS:BSC ENC 12IN400W |
| A032-412P |
EQPPS:PRE ENC 12IN400W |
| A032-418 |
EQBPS:BSC ENC 18IN400W |
| A032-418P |
EQPPS:PRE ENC 18IN400W |
| A032-420 |
EQBPS:BSC ENC 20IN400W |
| A032-425 |
EQBPS:BSC ENC 25IN400W |
| A032-425P |
EQPPS:PRE ENC 25IN400W |
| A032-432 |
EQBPS:BSC ENC 32IN400W |
| A032-432P |
EQPPS:PRE ENC32IN 400W |
| A032-435 |
EQBPS:BSC ENC 35IN400W |
| A032-438 |
EQBPS:BSC ENC 38IN400W |
| A032-438P |
EQPPS:PRE ENC 38IN400W |
| A032-442 |
EQBPS:BSC ENC 42IN400W |
| A032-442P |
EQPPS:PRE ENC 42IN400W |
| A032-448 |
EQBPS:BSC ENC 48IN400W |
| A032-448P |
EQPPS:PRE ENC 48IN400W |
| A032-450 |
EQBPS:BSC ENC 50IN400W |
| A032-450P |
EQPPS:PRE ENC 50IN400W |
| A032-455 |
EQBPS:BSC ENC 55IN400W |
| A032-455P |
EQPPS:PRE ENC 55IN400W |
| A032-460 |
EQBPS:BSC ENC 60IN400W |
| A032-460P |
EQPPS:PRE ENC 60IN400W |
| A032-465 |
EQBPS:BSC ENC 65IN400W |
| A032-465P |
EQPPS:PRE ENC 65IN400W |
| A032-472 |
EQBPS:BSC ENC 72IN400W |
| A032-472P |
EQPPS:PRE ENC 72IN400W |
| A032-477 |
EQBPS:BSC ENC 77IN400W |
| A032-477P |
EQPPS:PRE ENC 77IN400W |
ELECTRONIC
POWER SUPPLIES ( BALLASTS )

Our New
Electronic Power Supplies include; single or Dual 400
Watt, 3000 Watt, and 1800 Watt.
While most of these power supplies operate from a 208 -
230Vac line, The 1800 Watt offers the most amount of power
possible for a 110Vac outlet.
A few additional benefits include:
Assembly
Two wires for voltage in - two wires for voltage out to
lamp
Turning the lamp on and off only requires a simple switch
across two contacts. Also with the 1800W and 3000W
versions, various additional ready and fault indicators
can be monitored through your PLC, or through the use of a
separate control module, available separately.
Dimming
Using the old technology requires high voltage relays,
switches etc. Ours requires a low voltage switch.
Weight
Old technology for a 3,000W could be over 75 pounds. With
the electronic power supply weighing less than 8 pounds,
we can be truly portable or hand held.
Lamp Output
Electronic power supplies produce a smoother, more
consistent lamp output, resulting in longer lamp life and
cleaner lamp ends (less blackening)
A015-001ELECTRONIC
PS 400W
A015-002ELECTRONIC
PS 400W X2
A015-003ELECTRONIC
PS 1800W
A015-004ELECTRONIC
PS 3000V
LAMP
VOLTAGE INTERFACE LVI

Consistent
electrical draw by a UV curing system is essential to
maintaining peak UV lamp performance. With reliable
electrical service, UV curing lamps will perform with
greater predictability to deliver more consistent,
repeatable results. The Lamp Volt Interface (LVI), a fully
compatible volt measurement device, monitors this draw and
can be installed into any Con-Trol-Cure or 3rd party UV
curing system.
The LVI integrates parallel to your curing equipment's
power supply and irradiator to provide continuous feedback
of voltage level during operation. When interfaced with a
high impedance panel-mount volt meter, the LVI provides a
numerical power reading of lamp energy draw. The operator
can use this numerical value to determine when a lamp
stabilizes and is ready for use. This numerical value is
critical in establishing an initial baseline after
installing a new lamp.
As the lamp degrades over time, or if air flow (cooling)
within the housing is increased and inadvertently lowers
lamp temperature, the lamp will draw less energy. As a
result, the LVI’s numerical reading will be less than
its initial baseline. This indicates the lamp is drawing
less power and may be performing at less than peak
efficiency.
By noting this change in numerical values, you can quickly
cross-check this variance through physical cure evaluation
before under-cured product is generated. If the tested
product fails to cure at this numerical value, you can
eliminate the inefficiency by changing the lamp,
increasing power, or by changing air flow characteristics.
STANDARD FEATURES:
• Directly reports lamp condition
• Integrates into any UV curing system
• Assists in identifying poor performance
• Translates high voltage for use with standard
voltmeters
• Provides visual, numerical energy values for use in
determining lamp performance
• Easy to install and access
• Mounts parallel to lamp wiring to provide direct
reading
OPTIONAL FEATURES:
• Panel-mount volt meter display
A004-003STEP
DN TRNSFRMR 100/1
A004-004VOLTMETER:
TRMS
A004-005LAMP
VOLTAGE INTERFACE PANEL MOUNT
A004-006STPDN
TRNSRMR PNL MNT+
LIGHTHOUSE
SYSTEMS (UV REFLECTOR HOUSING)

Lighthouse UV
Curing Systems feature Con-Trol-Cure’s patented, highly
focused reflector geometry and new housing architecture to
deliver higher UV cure energy, greater energy efficiency,
and cooler running systems than comparable UV irradiators.
This performance, combined with Lighthouse's design
flexibility enables exceptional performance and efficient
operation for virtually all UV curing processes.
Due to their patented design features, Lighthouse UV
Curing Systems offer unparalleled performance at highly
competitive prices. Each extruded aluminum housing
dissipates heat more efficiently than traditional designs
while maintaining the lamp's desired operating temperature
for consistent cure results. Combined with Lighthouse's
optimally focused reflector geometry, each system
generates 20% more energy at the substrate surface than
other systems.
Lighthouse UV Curing Systems have been designed with the
user in mind. Lamp and reflector replacement requires less
than 5 minutes labor due to the system's quick-release
hardware. Built-in mounting channels along 3 sides of the
lamp housing make new installations or retrofits simple.
As well, the universal lamp holder accepts virtually all
popular makes of lamp.
UNIQUE AIR FLOW DESIGN
By replacing the aluminum extrusion found in most UV lamp
housings with a unique multi-rib system, the Lighthouse's
air flow pattern permits unobstructed cooling throughout
the housing. The innovative v-shaped reflector is also
supported in a manner to create an air channel along the
inside of the reflector. As the air is directed along the
reflector so as not to interfere with lamp performance,
overall efficiency is maintained. Fan-blown air also flows
along the outside of the reflector so both sides are
cooled simultaneously.
VERSATILE DESIGN
The Lighthouse's universal lamp holders feature a swivel
clamping system which accepts any lamp of any manufacturer
-- ceramic or metal end fitting. This system also permits
the adjustment of lamp focus to ensure that any lamp can
be placed in exact focus position for optimal performance.
The universal mounting channels allow for a quick and easy
retrofit into any 3rd party production system,
LIGHTHOUSE 3/4 ELLIPTICAL HOUSING
For 2-dimensional product applications, Lighthouse 3/4
Elliptical UV Curing Systems (shuttered or unshuttered)
offer a compact design and tight energy focus for easy
installation on printing presses, conveyors and in-line
coating operations.
• Custom arc lengths from 2” to 77”. For 77+",
please call. Special options are available.
• Available shuttered or non-shuttered.
LIGHTHOUSE 10" FOCUS HOUSING
This unique focus geometry, utilizing the Lighthouse
housing, allows the UV lamp to be placed 10" away
from your substrate. By creating this large distance
between the lamp and your product, many benefits are
realized. Cooling is much easier and more heat sensitive
substrates can be UV cured. As well, the farther away a UV
lamp is from the substrate, the smaller the angle of
incidence is. That is, the light hitting your product is
entering at a more perpendicular angle, with less UV light
being deflected off at odd angles. Therefore, more light
penetrates your ink or coating and your curing power is
magnified. This technology is also available in a 2-lamp
system called the Lighthouse Dual Cure.
View Comparison
The Dual Cure works in the same way as the 10" Focus
Housing, however, 2 lamps are configured in the housing,
creating extraordinary curing power. While there are just
2 lamps providing the curing in this system, it cures with
the power, intensity and speed of comparable 3-lamp
configurations. The addition of the 2nd curing lamp gives
this system a 130% boost over a singular 10" focus
lamp.
LIGHTHOUSE CURE TUNNEL
This 4 lamp, 400W/in curing system outperforms the
competition, while maintaining the value pricing that
CON-TROL-CURE is known for. Utilizing its patented housing
geometry, the Cure Tunnel™ represents the next
generation in high-speed, 3-D curing.
The 4 asymmetrically mounted lamps in the Cure Tunnel™
provide curing power to the substrate utilizing a unique
and efficient layout. Each of the 400W/in lamp units is
fixed at a 45° angle. This exclusive configuration
enables this unit to outperform systems retailing at
nearly 2-1/2 times the price! The Cure Tunnel™ even has
power to spare. A current customer has exhibited
satisfactory cure while running their system at only
half-power (200W/in). The dual lamp layout allows for
greater air circulation, keeping the substrate
significantly cooler than traditional lamp configurations.
Recent performance tests verified that under normal
operating conditions, these lamps impart minimal heat onto
the substrate. A galvanized steel pipe left the Cure
Tunnel™ with an exit temperature of 76°F. Such a
dramatic reduction in temperature over comparable systems
means heat sensitive substrates (plastic, PVC, etc.) can
be cured using the Cure Tunnel™.
THE ROTATOR™-- The new alternative to shuttered
systems
For UV curing systems over 36", shuttered housings
pose a problem due to the flexibility and play that the
shutters allow when they reach these lengths. As they heat
up, this problem is magnified. In order to achieve the
desired UV light elimination, most competing systems
simply line-up 2 shorter housings, end-to-end. A better,
alternative solution has been devised. Introducing the
CON-TROL-CURE™ Rotator™ system. Instead of attempting
to close long, warped shutters, the Rotator™ actually
rotates the lamp housing itself. Using an innovative ball
bearing hinge, the Rotator™ rotates the housing 90°,
allowing the light to be safely captured in a capture box.
The Rotator™ length is limited only by the length of
your lamp.
Whether you are installing a new UV curing system or
looking to upgrade or retrofit an existing production
line, UV Process Supply offers Lighthouse systems and
components to meet your specific requirements. From
conventional conveyorized applications to purpose-built
systems for high-speed, 3-D applications, UV Process can
provide cost-effective solutions for all of your UV curing
needs.
Give us a call to discuss how UV Process Supply’s
Lighthouse UV Curing Systems can be put to work for you in
your applications.
| A003-004 |
EQLH:SHUTTEREXTRUSIONS |
| A012-010 |
EQLH:VARIABLE UV SYSTM |
| A012-015 |
EQLH:SHUTTERED SYSTEM |
| A012-016 |
CONV:CONVEYORZED SYSTM |
| A012-017 |
EQLH:IRRADIATOR |
| A012-026 |
EQUIP:SYSTEM 10INFOCUS |
| A012-028 |
CONV:CONV 12X36IN |
| A013-0-- |
EQLH:CUSTOM IRRADIATOR |
| A013-006N |
EQLH:STD NONSH 6IN |
| A013-006NT |
EQLH:STD NONSH 6IN W/T |
| A013-008N |
EQLH:STD NONSH 8IN |
| A013-008NT |
EQLH:STD NONSH 8IN W/T |
| A013-010FS |
EQLH:10IN FOCUS SHUT |
| A013-010N |
EQLH:STD NONSH 10IN |
| A013-010NT |
EQLH:STD NONSH10IN W/T |
| A013-012N |
EQLH:STD NONSH 12IN |
| A013-012NT |
EQLH:STD NONSH12IN W/T |
| A013-015N |
EQLH:STD NONSH 15IN |
| A013-015NT |
EQLH:STD NONSH15IN W/T |
| A013-015ST |
EQLH:STD SHUT 15IN W/T |
| A013-018NT |
EQLH:STD NONSH18IN W/T |
| A013-020N |
EQLH:STD NONSH 20IN |
| A013-020NT |
EQLH:STD NONSH20IN W/T |
| A013-024N |
EQLH:STD NONSH 24IN |
| A013-024NT |
EQLH:STD NONSH24IN W/T |
| A013-025N |
EQLH:STD NONSH 25IN |
| A013-025NT |
EQLH:STD NONSH25IN W/T |
| A013-028NT |
EQLH:STD NONSH28IN W/T |
| A013-030N |
EQLH:STD NONSH 30IN |
| A013-030NT |
EQLH:STD NONSH30IN W/T |
| A013-032N |
EQLH:STD NONSH 32IN |
| A013-032NT |
EQLH:STD NONSH32IN W/T |
| A013-036N |
EQLH: STD NONSH 36IN |
| A013-038N |
EQLH:STD NONSH 38IN |
| A013-038NT |
EQLH:STD NONSH38IN W/T |
| A013-040N |
EQLH:STD NONSH 40IN |
| A013-040NT |
EQLH:STD NONSH40IN W/T |
| A013-042N |
EQLH:STD NONSH 42IN |
| A013-042NT |
EQLH:STD NONSH42IN W/T |
| A013-048N |
EQLH:STD NONSH 48IN |
| A013-048NT |
EQLH:STD NONSH48IN W/T |
| A013-050N |
EQLH:STD NONSH 50IN |
| A013-050NT |
EQLH:STD NONSH50IN W/T |
| A013-052N |
EQLH:STD NONSH 52IN |
| A013-052NT |
EQLH:STD NONSH52IN W/T |
| A013-055N |
EQLH:STD NONSH 55IN |
| A013-055NT |
EQLH:STD NONSH55IN W/T |
| A013-060N |
EQLH:STD NONSH 60IN |
| A013-060NT |
EQLH:STD NONSH60IN W/T |
| A013-065N |
EQLH:STD NONSH 65IN |
| A013-065NT |
EQLH:STD NONSH65IN W/T |
| A013-072NT |
EQLH:STD NONSH72IN W/T |
| A013-077N |
EQLH:STD NONSH 77IN |
| A013-077NT |
EQLH:STD NONSH77IN W/T |
| A143-003 |
EQUIP:UV CHAMBR LVH300 |
| A143-004 |
EQUIP:UV CHAMBR LVH750 |
UV
EQUIPMENT PARTS & ACCESSORIES
| A004-016 |
EQUIP:SWITCH DISC 100A |
| A005-000 |
CABLE 18AWG/6CONDUCTOR |
| A005-000BLK |
CABLE:12AWG/3CONDUCT |
| A005-017 |
EQUIP:CABLE HI VOLTAGE |
| A005-018 |
EQUIP:CABLE IRRADIATOR |
| A005-019 |
EQUIP:VALVE SHTR 110V |
| A005-020 |
EQUIP:VALVE SHTR 220V |
| A005-021 |
EQUIP:PS QK DISC-MALE |
| A005-022 |
EQUIP:PS QK DISC FEMAL |
| A005-023 |
EQUIP:FAN TIMER |
| A005-024 |
EQUIP:RELAY CON 230/60 |
| A009-001 |
FLTR:DICHROIC MATERIAL |
| U002-002 |
CONBLT:KEVLAR THREAD |
| U004-011 |
EQLH:REFLECTR KIT PARA |
| U004-012 |
EQLH:REFLECTRKIT 10INF |
| U004-014 |
EQLH:REFLECTR END PARA |
| U004-015 |
EQLH:REFLECTREND 10INF |
|